51 research outputs found

    Sex-specific efficacy and safety of cryoballoon versus radiofrequency ablation for atrial fibrillation: An individual patient data meta-analysis

    Get PDF
    BACKGROUND: Atrial fibrillation (AF) is a growing health burden, and pulmonary vein isolation (PVI) using cryoballoon (CB) or radiofrequency (RF) represents an attractive therapeutic option. Sex-specific differences in the epidemiology, pathophysiology, and clinical presentation of AF and PVI are recognized. OBJECTIVE: We aimed at comparing the efficacy, safety, and procedural characteristics of CB and RF in women and men undergoing a first PVI procedure. METHODS: We searched for randomized controlled trials and prospective observational studies comparing CB and RF ablation with at least 1 year of follow-up. After merging individual patient data from 18 data sets, we investigated the sex-specific (procedure failure defined as recurrence of atrial arrhythmia, reablation, and reinitiation of antiarrhythmic medication), safety (periprocedural complications), and procedural characteristics of CB vs RF using Kaplan-Meier and multilevel models. RESULTS: From the 18 studies, 4840 men and 1979 women were analyzed. An analysis stratified by sex correcting for several covariates showed a better efficacy of CB in men (hazard ratio for recurrence 0.88; 95% confidence interval 0.78-0.98, P = .02) but not in women (hazard ratio 0.98; 95% confidence interval 0.83-1.16; P = .82). For women and men, the energy source had no influence on the occurrence of at least 1 complication. For both sexes, the procedure time was significantly shorter with CB (-22.5 minutes for women and -27.1 minutes for men). CONCLUSION: CB is associated with less long-term failures in men. A better understanding of AF-causal sex-specific mechanisms and refinements in CB technologies could lead to higher success rates in women

    A Micro-Thermal Sensor for Focal Therapy Applications

    Get PDF
    There is an urgent need for sensors deployed during focal therapies to inform treatment planning and in vivo monitoring in thin tissues. Specifically, the measurement of thermal properties, cooling surface contact, tissue thickness, blood flow and phase change with mm to sub mm accuracy are needed. As a proof of principle, we demonstrate that a micro-thermal sensor based on the supported “3ω� technique can achieve this in vitro under idealized conditions in 0.5 to 2 mm thick tissues relevant to cryoablation of the pulmonary vein (PV). To begin with “3ω� sensors were microfabricated onto flat glass as an idealization of a focal probe surface. The sensor was then used to make new measurements of ‘k’ (W/m.K) of porcine PV, esophagus, and phrenic nerve, all needed for PV cryoabalation treatment planning. Further, by modifying the sensor use from traditional to dynamic mode new measurements related to tissue vs. fluid (i.e. water) contact, fluid flow conditions, tissue thickness, and phase change were made. In summary, the in vitro idealized system data presented is promising and warrants future work to integrate and test supported “3ω� sensors on in vivo deployed focal therapy probe surfaces (i.e. balloons or catheters)

    Atrial arrhythmogenicity in aged Scn5a+/∆KPQ mice modeling long QT type 3 syndrome and its relationship to Na+ channel expression and cardiac conduction

    Get PDF
    Recent studies have reported that human mutations in Nav1.5 predispose to early age onset atrial arrhythmia. The present experiments accordingly assess atrial arrhythmogenicity in aging Scn5a+/∆KPQ mice modeling long QT3 syndrome in relationship to cardiac Na+ channel, Nav1.5, expression. Atrial electrophysiological properties in isolated Langendorff-perfused hearts from 3- and 12-month-old wild type (WT), and Scn5a+/∆KPQ mice were assessed using programmed electrical stimulation and their Nav1.5 expression assessed by Western blot. Cardiac conduction properties were assessed electrocardiographically in intact anesthetized animals. Monophasic action potential recordings demonstrated increased atrial arrhythmogenicity specifically in aged Scn5a+/ΔKPQ hearts. These showed greater action potential duration/refractory period ratios but lower atrial Nav1.5 expression levels than aged WT mice. Atrial Nav1.5 levels were higher in young Scn5a+/ΔKPQ than young WT. These levels increased with age in WT but not Scn5a+/ΔKPQ. Both young and aged Scn5a+/ΔKPQ mice showed lower heart rates and longer PR intervals than their WT counterparts. Young Scn5a+/ΔKPQ mice showed longer QT and QTc intervals than young WT. Aged Scn5a+/ΔKPQ showed longer QRS durations than aged WT. PR intervals were prolonged and QT intervals were shortened in young relative to aged WT. In contrast, ECG parameters were similar between young and aged Scn5a+/ΔKPQ. Aged murine Scn5a+/ΔKPQ hearts thus exhibit an increased atrial arrhythmogenicity. The differing Nav1.5 expression and electrocardiographic indicators of slowed cardiac conduction between Scn5a+/ΔKPQ and WT, which show further variations associated with aging, may contribute toward atrial arrhythmia in aged Scn5a+/ΔKPQ hearts

    Detailed Anatomical and Electrophysiological Models of Human Atria and Torso for the Simulation of Atrial Activation

    Get PDF
    Atrial arrhythmias, and specifically atrial fibrillation (AF), induce rapid and irregular activation patterns that appear on the torso surface as abnormal P-waves in electrocardiograms and body surface potential maps (BSPM). In recent years both P-waves and the BSPM have been used to identify the mechanisms underlying AF, such as localizing ectopic foci or high-frequency rotors. However, the relationship between the activation of the different areas of the atria and the characteristics of the BSPM and P-wave signals are still far from being completely understood. In this work we developed a multi-scale framework, which combines a highly-detailed 3D atrial model and a torso model to study the relationship between atrial activation and surface signals in sinus rhythm. Using this multi scale model, it was revealed that the best places for recording P-waves are the frontal upper right and the frontal and rear left quadrants of the torso. Our results also suggest that only nine regions (of the twenty-one structures in which the atrial surface was divided) make a significant contribution to the BSPM and determine the main P-wave characteristics.This work was partially supported by the "VI Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica" from the Ministerio de Economia y Competitividad of Spain and the European Commission (European Regional Development Funds - ERDF - FEDER), Award Number: TIN2012-37546-C03-01 (Recipient: Ana Ferrer); the "Programa Estatal de Investigacion, Desarrollo e Innovacion Orientado a los Retos de la Sociedad" from the Ministerio de Economia y Competitividad and the European Commission (European Regional Development Funds - ERDF - FEDER), Award Number: TIN2014-59932-JIN (Recipient: Rafael Sebastion); and the "Programa Prometeo" from the Generalitat Valenciana, Award Number: 2012/030 (Recipient: Laura Martinez).Ferrer Albero, A.; Sebastián Aguilar, R.; Sánchez Quintana, D.; Rodriguez, JF.; Godoy, EJ.; Martinez, L.; Saiz Rodríguez, FJ. (2015). Detailed Anatomical and Electrophysiological Models of Human Atria and Torso for the Simulation of Atrial Activation. PLoS ONE. 10(11):1-29. https://doi.org/10.1371/journal.pone.0141573S129101

    Splenomegaly, anaemia and pleural effusion

    No full text

    A mysterious cause of constrictive pericarditis: unfolding of the missing link

    No full text
    10.1093/ehjci/jex339European heart journal cardiovascular Imaging19447

    Cardiac resynchronisation therapy in the presence of left-to-right intracardiac shunting: More good than harm?

    No full text
    10.1136/bcr-2015-213908BMJ Case Reports2016bcr2015213908

    Splenomegaly, anaemia and pleural effusion

    No full text
    No abstract available

    Left ventricular pacing in patients with preexisting tricuspid valve disease

    No full text
    10.1002/joa3.12257Journal of Arrhythmia356836-84
    corecore